Integra-TR is bought to transfer small portions of data between the facility equipment and the control center. Pumping station, water intake, metering device and distributed technical facility require different exchange conditions. To buy a suitable radio modem, start with the full code of the device and a description of the existing or projected network.

Catalogue image of radio modem family Integra
Catalog image of the Integra family: ANTENNA, SETUP and COM connectors are visible. The full code, hardware version, condition and set of the instance are confirmed separately.

What position we propose to discuss

In our catalogue, CalAmp DataRadio Integra-TR 242-4018-630 is listed as configuration 150-174 MHz. In the request, save the entire code, including the last three digits. For the supplied instance, we separately confirm the marking, hardware version, condition and documentation.

The Integra-TR family name appears in the manuals of different years. The manual code table PN 001-4008-100 Rev 3, April 2012, gives the configuration Dual IF, and a separate line 242-4018-630 is not. Therefore, the parameters of the entire line and sets of bands from this table cannot be automatically attributed to the warehouse position. If you need to replace an existing modem, attach a label to both ends of the line.

Table of initial data for purchase

What to reportWhy do you need it?
Full code and photo tagInstall configuration and applicable documentation
Operating frequencies and channel bandComparison of equipment with the existing network
Controller model and portCheck the electrical interface and cable
Interview period and size of exchangeEvaluate delays, repetitions and time of the channel
Power supply and installation siteHarmonize power supply, protection and cooling
Number of nodes and city of receiptPrepare a statement and terms of delivery

COM and radio channels are checked separately

The family guide describes a COM with an RS-232 interface for hardware and a separate SETUP for customization. Serial port speed and radio exchange rate are different parameters. The same number in UART settings does not prove the compatibility of two radio modems.

For example, the controller may have an RS-485, an Ethernet, or just a USB. Having a similar connector does not make it an RS-232. For such an object, the interface conversion is first selected and verified. Integra-TR itself does not become an Ethernet switch or cellular router, thanks to the word “modem” in the title.

The finished line includes more than two boxes.

In the application, separate devices, antennas, feeders, adapters, power supply and installation. For each node, write down the placement conditions, the length of the cable and the type of connectors. The catalog image shows the device; it does not confirm the presence of all accessories in the proposed kit.

The antenna path is selected for the actual frequency and interface of the device. The MIG WIMAX Panel 2.6-14 is a different frequency direction and is not a VHF antenna for the Integra-TR. If a separate cellular channel is planned at the facility, its set is considered separately.

New network and expansion require different information

For the new network, a scheme with node coordinates, suspension heights, the required polling period and energy sources is useful. To expand the existing network, you need installed base data, modem version and agreed settings. In the second case, an existing channel sets restrictions for the purchase of a new node.

If the equipment transmits emergency events, state the allowable delay and behavior of the system when the data is missed. Radio communication is evaluated as part of the project and tests at the facility. The mere presence of a transparent exchange does not guarantee the receipt of each message or a pre-defined range.

What to get in quotation

Ask to record the product code, condition, scope of supply, documentation and verification procedure. It is convenient for the party to attach a table of nodes: the place of installation, role, equipment and necessary accessories. This allows you to separate the price of the modem from the cost of the finished line and compare the quotation by the same volume.

“Please request quotation on Integra-TR 242-4018-630 for [objects]. The number of nodes is [value], equipment and ports are [models]. Frequencies and parameters of the existing network are included. Receiving is [city]. Confirmation of configuration, kit and delivery conditions are required.”

Current availability and cost are confirmed in response to the request. For the calculation of the exchange cycle use technical guideand for a separate cellular direction, telemetry comparison.

Request for delivery and city of receipt

To buy Integra-TR for an object or lot, specify the city: Moscow, Novosibirsk, Omsk, Almaty or another point in Russia and Kazakhstan. Attach the full designation, the number by configuration and the requirements for the kit. The cost, current availability and delivery conditions will be confirmed in the quotation.

Questions before ordering

Can I order an Integra-TR without the full code?

For accurate selection, you need complete code and network data. The parameters of the neighboring configuration do not confirm the compatibility of the proposed device.

Will the MIG WIMAX Panel fit this VHF modem?

This panel refers to a different frequency direction. The Integra-TR antenna is selected according to the operating frequency and connectors of a particular apparatus.

The photo confirms the presence and the whole set?

Photo shows a catalog device. The current availability, condition and list of accessories are recorded in the quotation.

Selection materials

Family documentation: CalAmp PN 001-4008-100 Rev 3, April 2012; Guide at CalAmp, Rev 6, February 2013. Code 242-4018-630 is agreed on the marking and applicable documentation of the instance; the common table of other configurations does not confirm the finished replacement.

Buy a specific radio modem

Integra radio modem from the OmegaIntegral catalog

Integra-TR 242-4018-630: Trade card

Catalog designation: 150–174 MHz configuration, status, documentation and accessories of a specific delivery are confirmed upon request.

Request quotation: office@omegaintegral.ru · +7 (3812) 490-00-02. Specify the equipment models, the amount and place of receipt.

Buying telemetry equipment

Current availability, configuration, kit, cost and delivery terms are confirmed by e-mail.